WALL CONSTRUCTION

The wall is made of cold-formed steel girts to which profiled steel wall panels are attached. The steel girts are galvanised on both sides with a zinc layer with a total thickness of 275 g/m² (Z-275). The wall panels are zinc-coated on both sides. The front side is coated with a polyester layer in a RAL colour. The rear side is coated with a light grey primer.
The wall panels are attached using self-tapping screws. The underside of the panelling is finished with a sill profile.
The wall panelling starts at level +0,35 m, from the concrete foundation beam.

WALL INSULATION

The insulation consists of mineral wool insulation plates, with a total thickness of 200 mm and with a U coefficient ≤ 0,18 W/m²K. The plates are applied between wall panels.

LINER PANELLING

For the internal system walls, profiled steel panels are applied to the inside of the wall girts. The panels are zinc-coated on both sides. The visible side is coated with a polyester layer in a RAL colour. The rear side is coated with a light grey primer. The wall panelling starts at level +0,35 m, from the concrete foundation beam.